How much heat
does your room need?
Enter your rooms, compare suitable output options and explore heaters with optional lighting. The first step towards your individual heating solution.
The calculation is non-binding and does not replace a property-specific heating load calculation under DIN EN 12831. Results and product suggestions are neither an offer nor a guarantee of suitability, consumption or room temperature. Before purchase and installation, have the heating load, installation site, electrical connection, controls and legal requirements checked professionally.
Checking offline files …
MOBILE APP
Install the Infrared Planner
Install the ThermoSolutions Infrared Planner directly on your device. The calculation is the same as on infrarotplaner.de.
The app does not require an account. The offline feature does not store room or project data in the app cache.
THE BASICS
Your project
Enter numbers without thousands separators. You may use a full stop or comma as the decimal separator.
How is it calculated?
Floor area × actual ceiling height × assigned volume reference value = estimated heating requirement in watts. Any allowance you choose is added separately. For model selection, the result for each room is rounded up to the next whole watt.
The default is Typical building from 2008 / C / HWB approximately 100 kWh/m² per year, using 22 W/m³.
This application uses the actual ceiling height you enter.
Annual space heating demand (HWB) and heating output are different quantities. The HWB figures in kWh/m² per year are used here only to describe the table categories. They are not converted directly into watts or presented as calculated annual electricity consumption or a running cost forecast. The selection does not determine your building's energy class.
Alternatively, you can enter a room heating load already determined by a professional. The table category is then not used to calculate that room's output requirement. The app does not independently calculate climate, heat losses through individual building components, air changes or target temperature. An unsuitable reference value can lead to undersizing or oversizing.
The table values provide guidance only.
Understanding radiant efficiency
Radiant efficiency is not overall electrical efficiency. For direct electric heaters, it describes radiant performance under defined test conditions. DIN EN IEC 60675-3:2021-12 specifies a measurement method for this purpose.
The calculator therefore does not adjust the estimated heating requirement using radiant efficiency. Example: a room with an estimated requirement of 1,100 W still requires coverage by 1,100 W of rated thermal output. A radiant efficiency of 60%, for example, would not mean that only 60% of the electrical power becomes heat; it describes how heat output is divided between radiation and other heat transfer mechanisms.
A higher radiant share can influence the direct warming of room surfaces and the mean radiant temperature. It does not imply proportional electricity savings. The building envelope, target temperature, controls, use and mounting position remain essential to heating demand and comfort.
ROOM BY ROOM
Your rooms
OUTPUT MEETS DESIGN
Your model suggestions
The suggestions meet your calculated heating requirement. You can select an option for each room and add lighting accessories with documented compatibility. Radiant efficiency is not used as an output or consumption factor. References to standards are shown only where documented in the stored product data. Data source: September 2026 catalogue edition; availability is not checked live.
Selection rules and lighting status explained
Selection considers your preferred installation, heater type, manufacturer and lighting preference. Lower excess output and a manageable heater count are preferred. In addition to identical models, each range may include a combination of two models. When calculated results are equal, classic panels and documented lighting accessories take priority. Where suitable, the compact preview includes both manufacturers. An absolute optimum across every possible combination is not guaranteed.
For easyTherm, automatic selection requires at least one heater per 30 m² or part thereof, for example three heaters for 65 m². For REDWELL, a separate rule requires at least two heaters above 30 m². A manually chosen minimum replaces this rule. Actual positioning and heat distribution require separate planning. If the required minimum exceeds the selected maximum, no suitable option is shown.
Yes: A model-specific light frame is listed. No, according to the catalogue: The documentation explicitly excludes one. Check compatibility: A compatible version is not clearly documented. Not specified: The catalogue lists no matching accessory; this does not prove that none is available.
Lighting power is shown separately and does not count towards the heating requirement. REDWELL light frames are rated IP20 according to the catalogue. A heater's IP rating does not automatically apply to its light frame.
Radiant efficiency: For some product ranges, the stored catalogue documents a reference to testing under IEC 60675-3:2020. Where no model-specific percentage is provided, no value is estimated. Missing information is not interpreted as lower efficiency and does not affect the ranking of suggestions.
OPTIONAL · YOUR OWN SCENARIO
Explore running costs
The building category's HWB figures are not used as electricity consumption. This is not a consumption forecast: the scenario multiplies the selected heater output by your own operating assumptions and electricity unit price.
Equivalent full-load hours represent calculated hours at full rated output, not simply the time a thermostat is switched on. Lighting, hot water, standing charges, other appliances and any on-site electricity generation are excluded.
YOUR NEXT STEP
Take your results with you.
Plan the next steps together.
Your printout includes room data, calculation assumptions, selected heater models and lighting accessories. It carries the ThermoSolutions contact details and is clearly labelled as non-binding guidance.
View the stored product selection
The database contains heater models and technical variants for space heating. Hot water cylinders, underfloor heating mats, outdoor surface heating, pipe trace heating and control accessories are not suggested as interchangeable heating panels. Special heaters for workstations, outdoor areas or industry are labelled for information and excluded from automatic selection.
This application shows output options, not a fully designed heating system. Confirm technical data, availability and accessories against current manufacturer documentation before ordering. Product names and trademarks remain the property of their respective owners.